BI Connector ODBC Driver vulnerability

The MongoDB BI Connector ODBC Driver converts floating point column values into text without checking that the result fits within the destination buffer. When an application reads a sufficiently large floating point value as text, the driver may write beyond the end of that buffer and corrupt adjacent memory. A user who can store data in a collection read through the BI Connector could use this to crash the application performing the read.

Published 12 Aug 2026Updated 11 Sep 20261 sources
CVSS 7.1

What happened

The MongoDB BI Connector ODBC Driver converts floating point column values into text without checking that the result fits within the destination buffer. When an application reads a sufficiently large floating point value as text, the driver may write beyond the end of that buffer and corrupt adjacent memory. A user who can store data in a collection read through the BI Connector could use this to crash the application performing the read.

Affected versions

BI Connector ODBC Driver: 1.0.0 through before 1.4.9 (semver) Fixed: See vendor advisory.

Why it matters

Review the vendor advisory and exposure of the affected product to determine operational impact.

Detection & mitigation

  • Apply vendor-provided updates or mitigations.
  • Review affected product exposure and access logs.

Public PoC references

No public PoC reference has passed the current publication threshold.