Cisco Secure Firewall Management Center (FMC) vulnerability

A vulnerability in the External Database Access feature of Cisco Secure Firewall Management Center (FMC) Software could allow an unauthenticated, remote attacker to execute arbitrary commands as root on an affected device. This vulnerability is due to insecure deserialization of a user-supplied Java byte stream from a host that is configured in the external database access list. An attacker could exploit this vulnerability by sending a crafted, serialized Java byte stream to a specific TCP port of an affected device. A successful exploit could allow the attacker to execute arbitrary commands on the device and elevate privileges to root. Notes: This vulnerability can be exploited only by an attacker who has control of a host in the external database access list. If the FMC management interface does not have public internet access, the attack surface that is associated with this vulnerability is reduced.

Published 16 Sep 2026Updated 18 Sep 20261 sources
CVSS 9.8

What happened

A vulnerability in the External Database Access feature of Cisco Secure Firewall Management Center (FMC) Software could allow an unauthenticated, remote attacker to execute arbitrary commands as root on an affected device. This vulnerability is due to insecure deserialization of a user-supplied Java byte stream from a host that is configured in the external database access list. An attacker could exploit this vulnerability by sending a crafted, serialized Java byte stream to a specific TCP port of an affected device. A successful exploit could allow the attacker to execute arbitrary commands on the device and elevate privileges to root. Notes: This vulnerability can be exploited only by an attacker who has control of a host in the external database access list. If the FMC management interface does not have public internet access, the attack surface that is associated with this vulnerability is reduced.

Affected versions

Cisco Secure Firewall Management Center (FMC): 7.0.0; 7.0.0.1; 7.0.1; 7.0.1.1; 7.0.2; 7.2.0; 7.0.2.1; 7.0.3; 7.2.0.1; 7.0.4; 7.2.1; 7.0.5; 7.3.0; 7.2.2; 7.3.1; 7.2.3; 7.2.3.1; 7.2.4; 7.0.6; 7.2.4.1; 7.2.5; 7.3.1.1; 7.4.0; 7.0.6.1; 7.2.5.1; 7.4.1; 7.2.6; 7.4.1.1; 7.0.6.2; 7.2.7; 7.2.5.2; 7.3.1.2; 7.2.8; 7.6.0; 7.4.2; 7.2.8.1; 7.0.6.3; 7.4.2.1; 7.2.9; 7.0.7; 7.7.0; 7.4.2.2; 7.2.10; 7.6.1; 7.4.2.3; 7.0.8; 7.6.2; 7.7.10; 7.2.10.1; 7.0.8.1; 7.6.2.1; 7.2.10.2; 7.7.10.1; 7.4.2.4; 7.4.3; 7.6.3; 7.7.11; 7.6.4; 10.0.0; 7.4.4; 7.4.5; 7.0.9; 7.2.11; 7.7.12; 7.6.5; 7.4.6; 10.0.1; 7.4.7 Fixed: See vendor advisory.

Why it matters

Review the vendor advisory and exposure of the affected product to determine operational impact.

Detection & mitigation

  • Apply vendor-provided updates or mitigations.
  • Review affected product exposure and access logs.

Public PoC references

No public PoC reference has passed the current publication threshold.